NYC PT2 Tender

Discuss All Facets of 2-Rail, 1/48 Scale, Model Railroading
Norton
Posts: 2244
Joined: Thu Aug 18, 2005 2:59 pm

NYC PT2 Tender

Postby Norton » Wed Dec 25, 2024 11:07 am

I would like to model a New York Central PT2 tender. It was unique to a single Hudson that ran on the Big 4. The plan is to use a PT4 tender as a starting point. I didn’t think anyone ever made a PT2 but some sources say possibly Max Gray or other early brass builders may have. Anyone know for sure if someone may have built one or better yet actually have this model. Am hoping to get a photo of the water deck to determine where the hatches should be placed.

Pete

Norton
Posts: 2244
Joined: Thu Aug 18, 2005 2:59 pm

Re: NYC PT2 Tender

Postby Norton » Wed Dec 25, 2024 3:55 pm

I was able to find out what some were referring to regarding a Max Gray PT2 Tender. They called this tender a PT2 but its not. Thats more like a PT1 tender.

https://www.brasstrains.com/Classic/Pro ... ede-Tender

A PT2 tender was used only with this engine. Clearly different than Max Gray’s version.

https://nycshs.omeka.net/items/show/88317

Looks like the search continues.

Pete

User avatar
sarge
Posts: 5138
Joined: Thu Apr 02, 2009 2:21 pm
Location: Dungfield Manor

Re: NYC PT2 Tender

Postby sarge » Wed Dec 25, 2024 5:19 pm

Pete:

You'll have to build/bash a PT2 if you really want one.

The PT2 had a far higher water capacity than the rest of the breed, the slope-sheet much further forward, and a far smaller coal bunker as a result. The PT2 was not equipped for scooping water. It rides on the same frame as the PT1, so you have that as the starting point.

The rest of what you read on forums like OGR is bollocks and is confusing you. This tank was built for water capacity whilst the rest of the PTs were built for coal capacity.

Max did a quasi-PT1, or more accurately a confused one. PT-1s were originally built without an air header/expansion chamber behind the slopesheet and no overflow pipes on the frame. They were retrofitted with both when uprated to match the PT4/PT5. These were built with the expansion system and thus equipped could take water from a pan at 70mph. Without, the cistern on the PT1 was known to split from the surge pressure if water was scooped at too high a speed. There are test photos to that effect. Max put the pipes on the frame but no header on the rear deck; can't have one without the other.

Your best bet is to use any of the PT frames and running gear, remove any overflow pipes and splash shields, then bash or build the superstructure from there.

Norton
Posts: 2244
Joined: Thu Aug 18, 2005 2:59 pm

Re: NYC PT2 Tender

Postby Norton » Wed Dec 25, 2024 5:42 pm

Sarge, I have an MTH PT tender. I have a pretty good idea what I have to do machining off the top but just haven’t found any photos of the deck on the PT2. I am assuming the water hatch and vents are not in the same place as even a PT1 but may just have to punt.
Besides the docs at the NYCHS I have Know thy Hudsons and a number of other books but I suppose since the PT2 was one of a kind there are few photos.

The tender on the first page behind the Dreyfuss appears to be what Max Gray modeled.

https://nycshs.org/wp-content/uploads/2 ... enders.pdf

Pete


Return to “O-Gauge, 2-Rail, Model Railroading”

Who is online

Users browsing this forum: No registered users and 48 guests